|
Name |
Description |
Aggregated SPM data provided by NHH DA (F3129)
|
F3129
Aggregated SPM data provided by NHH DA
Each metering point has one or more EAC and AA. The NHH DA sums the EACs and AAs for each supplier and settlement class and sends the aggregated values to the SVA Agent. This data is called the Supplier Purchase matrix (SPM)
D41: Supplier Purchase Matrix Data: Details of NHH Consumption per Supplier aggregated per BSP/GSP Group by profile class, line loss factor class and measurement requirement PLUS Line Loss Adjusted Aggregated Meter Data
|
Consumption Data to HH DA (F2404)
|
F2404
Consumption Data to HH DA
|
Daily Profiles (F3143)
|
F3143
Daily Profiles
|
DUoS Report (F1100)
|
F1100
DUoS Report
SVAA send the distributor business the DUoS Report
A report of profiled SPM data by settlement class (summed over Data Aggregators) for suppliers and distributors. The supplier report will contain the data for one supplier only. The distributor report will contain the data for all suppliers associated with the distributor. The report will include profiled SPM data and line loss factors for each HH per valid combination of Profile Class, standard settlement configuration and time pattern regime, per loss factor class, per supplier.
|
Failures / exceptions to NHH DC (F3860)
|
F3860
Failures / exceptions to NHH DC
|
Line Loss Adjusted Aggregated Meter Data (LLAAMD) (F3115)
|
F3115
Line Loss Adjusted Aggregated Meter Data (LLAAMD)
Flow Description: Jan 2001
---------------------------------------
The Half Hour Data Aggregators adjust the half hour values for each metering point for line loss, aggregate the values for all half hour metering points for a Supplier (by BM unit if appropriate), and supply the separate totals as an input into the SVA Agency for each half hour over the Settlement Day for use in the settlement runs
Change Record: Version 7.2
----------------------------------------
- Flow description changed to add reference to NETA
Change Record: Version 8.0
-----------------------------------------
- Reference to pre-NETA arrangements removed
D40: Aggregated line loss adjusted HH consumption figures by Supplier and By GSP Group.
|
NHH Consumption Data to DA (F2513)
|
F2513
NHH Consumption Data to DA
Metering Point EAC/AA Data to all affected NHH DA's
Details of the annualised advance and estimated annual consumption calculated by the NHH DC.
|
Profiling reports to DCs (F3082)
|
F3082
Profiling reports to DCs
Profiling reports to DC to allow EAC calculation.D18:Daily Profile Data Report: Details of the daily profile production process. D28:Standing Profile Data Report:A standing profile data report for one or all GSP Group containing data valid for a day.
|
Profiling reports to Suppliers (F3100)
|
F3100
Profiling reports to Suppliers
D18: Daily Profile Data Report: Details of the daily profile production process. D28:Standing Profile Data Report: A standing profile data report for one or all GSP Group containing data valid for a day.
|
Sunset Times (F3137)
|
F3137
Sunset Times
|
Teleswitch Instructions (F3078)
|
F3078
Teleswitch Instructions
|
Temperature data (F3077)
|
F3077
Temperature data
|